Description
| Input voltages | CSA | 480/600 V, 3-PH, 50/60 Hz |
|---|---|---|
| CE | 400 V, 3-PH, 50/60 Hz | |
| CCC | 380 V, 3-PH, 50/60 Hz | |
| Input current @ 21.9 kW | 300/400/480/600 V, 38/36/31/24 A | |
| Output current | 30–125 A | |
| Rated output voltage | 175 VDC | |
| Duty cycle @ 40° C (104° F) | 100% @ 125 A | |
| Open circuit voltage (OCV) |
| |
| Dimensions with handles | 592 mm D; 274 mm W; 508 mm H (23.3″ D; 10.8″ W; 20.0″ H) | |
| Weight with 7.6 m (25′) torch |
| |
| Gas supply | Clean, dry, oil-free air or nitrogen | |
| Recommended gas inlet flow rate/pressure | Cutting: 260 l/min (550 scfh) @ 5.9 bar (85 psi) Gouging: 212 l/min (450 scfh) @ 4.1 bar (60 psi) | |
| Input power cable length | 3 m (10′) * | |
| Power supply type | Inverter – IGBT | |
| Engine drive requirement | 40 kW for full 125 A output | |
| Certifications | CSA-certified for use in the Americas and Asia, except China. CE, C-Tick, CU/GOST, Ukr, and Serbian – for use in Europe, Australia, Belarus, Kazakhstan, Russia, Serbia, Ukraine, and other countries where accepted. CCC for use in China. | |
| Warranty | Power supplies have a 3-year warranty and torches a 1-year warranty. | |
Engine-driven generator operation
| Engine drive rating | System output current | Performance (arc stretch) |
|---|---|---|
| 40 kW | 125 A | Full |
| 30 kW | 125 A | Limited |
| 30 kW | 100 A | Full |
| 25 kW | 100 A | Limited |
| 22.5 kW | 75 A | Full |
| 20 kW | 75 A | Limited |
| 20 kW | 60 A | Full |
| 15 kW | 60 A | Limited |
| 12 kW | 40 A | Full |
| 10 kW | 40 A | Limited |
| 10 kW | 30 A | Full |
| 8 kW | 30 A | Limited |
Capacity
| Capacity | Thickness | Cut speed |
|---|---|---|
Cutting | ||
| Recommended | 38 mm (1-1/2″) | 457 mm/min (18 ipm) |
| 44 mm (1-3/4″) | 250 mm/min (10 ipm) | |
| Severance (hand cutting) | 57 mm (2-1/4″) | 125 mm/min (5 ipm) |
| Pierce * | 25 mm (1″) | |